CONSTRUCTION OF SHEEL AND TUBE HEAT EXCHANGER

Code: AB546860980421  Price: 4,000   61 Pages     Chapter 1-5    6370 Views

CONSTRUCTION OF SHEEL AND TUBE HEAT EXCHANGER

ABSTRACT

The aim of this project was to construct shell and tube heat exchanger with fixed boundless. A heat exchanger that would cool 5 x 5 x 10 – 3 kg/s of steam at a calculated heat load of 152 – 395/S was fabricated. The steam is to reach the heat exchanger from a distillation column at a temperature of 300k. The specification of the layout as well as the detailed mechanical design were assumed and also calculated.

It is established that a horizontal heat exchanger with cold water at the shall side and the treated steam at the tube side is adequate for this operation, with the aim of cooling the steam from the distillation column.

The available area obtained from calculation is 1.0m2 and also the overall heat transfer coefficient obtained is 4.10W/M2k. it is also seen that the heat exchanger is satisfactory and consists of five copper tubes of inside diameter 90mm and 5920mm length. The shell inside diameter 810mm and 5.770mm length. The tube and shell heat exchanger has a total length of 5820mm.

The material of construction for the shell side is stainless steel while copper tubes were used for the tubes inside.

The total cost of the heat exchanger was N12,000.

CHAPTER ONE

INTRODUCTION

In large industrial processes, it is necessary to transfer heat between the system and its surrounding and the device whose primary objective to do it efficiently and effectively is the heat exchanger.

Therefore heat transfer is defined as the rate of exchange of heat between one body (hot) and another cold.

The most important aim in the chemical engineering sector of any plant is to control the flow of thermal energy between two terminals. It there existing temperature gradient of change.

In industrial process, the heat exchange is a very important unit in all the processing industries that their design has been highly developed. Designers of heat exchanger must be constantly aware of the difference between the idealized conditions for and under which basic knowledge was obtained and the real conditions of the mechanical expressions of their design and it’s environment.

The design must satisfy process operational requirement such as availability and maintainability.

Heat transfer or thermo-kinetics is another chapter of the theoretical fundamentals of heat engineering dealing with the processes of heat propagation. In nature and engineering, the most diverce process of heat propagation are observed and also heat flow from bodies (or their section) of a lower temperature. During the process of heat transfer, from one body to another heat flow continues till their temperature became equal be come to equilibrium state of temperature.

MODES OF HEAT TRANSFER

Heat is transferred by conduction, convection and thermal radiation. In practice, heat is usually transmitted by two or all the three modes of heat transfer concurrently.

CONDUCTION

Heat conduction of simply conduction is the transfer of heat by a direct contact between the elementary particles of a body, Viz molecules, atoms, free electrons, when the bodies involved are at rest.

Pure conduction takes place in opaque or non transpired solid.

In goses, conduction occurs due to random motion of the molecules (the diffuse from high concentration region to lower region. In this made of heat transfer, it is very common with metals and thus call for high thermal conductivity. Also the heat transfer per unit area is proportional to normal temperature gradient given as:

Q = dt = (1)

A dx

Fourier postulated an expression for heat transferred by conduction called fouriers law gives by:

Q = KA dt = (2)

Dx

Where Q rate of flow of heat J/S or welts

K = Fourier’s constant

A = Area of heat transfer perpendicular to the direction of heat flow (M2).

dt/dx temperature gradient (0C or K ).

CONVECTION

This involves the transfer of heat from one body to another by the mobile particles of liquid, gas or coarse solids during their relative motion in space. Convection heat transfer can be illustrated by the transfer of heat by heated air from a stove to the upper layers of the room air. Convection consist of forced and natural convection. Forced convection is widely used in chemical processing industries. The expression below shows heat transfer by convection.

Q = KA (Ti – To) = (3)

= hA (Ti – To) = (4)

where h k/x

Q = heat transfer rate J/S or welts

K = Proportionality constant

X = Distance over which heat is transferred (m)

A = Area (M2)

Ti and To = Temperature at different point (0C or K)

h = Convection heat transfer co-efficient (w/m2k)

RADIATION

This is a process of heat transferred by electromagnetic waves through a machines which is transparent to thermal radiation. During this process, a fraction of the thermal energy of a hot body is converted into radiant energy which, when encountering an opaque body again turns partly into heat.

From the second law of thermodynamics, STEFANBOLTZ MANU prop

Proposed that heat is directly proportional to the fourth power of the temperature and the surface area.

Thus given as:

Q = såAT – 4 = (5)

Where s = Stefan – Boltman constant

å = Emissivity surface

T = Absolute temperature (0C or K)

A = Area of heat transfer (M2)

Q = Heat transfer rate J/S or welt

HEAT TRANSFER EQUIPMENT

There are various types of heat exchange equipment generally defined by the function it performs in a chemical industry. Generally, heat exchange is the equipment whose primary objective is to transfer heat energy between two fluids. These equipment are classified into three categories mainly:-

(a) Regenerators

(b) Open type heat exchangers and

(c) Closed type bread exchanger or recuperations

a. REGENERATORS

These are heat exchangers in which the hot and cold fluid flow through the same space alternatively with a little physical mixing as possible occurring between the two streams. The amount of heat transferred depends on the fluid and flow properties of the fluid streams as well as the geometry and thermal properties of the surface.

b. OPEN TYPE HEAT EXCHANGERS

These are devices where by fluid stream flow into an open chamber and there the complete mixing occurs. Hot and cold fluid enter the exchanger separately and will at the other end leaves as single fluid stream.

c. RECUPERATORS OR CLOSED TYPE HEAT EXCHANGERS

They are those in which the heat transfer occurs between the two fluid stream that do not physical contact each other. The fluid streams involved are separated from one another by a tube wall or a pipe. Heat transfer occurs by convection from the hot fluid to the solid surface, by conduction through the solid surface and then by convection through solid surface to the cooler fluid.

Another classification is based on relative flow direction of the two fluid streams. They include:-

i. Parallel Flow: When the fluid stream flow in the same direction.

ii. Counter Current Flow: The fluid streams flow in opposite direction.

iii. Cross Flow: If the fluid stream flow at right angle to one another.

The other classification is based on tube construction:-

i. Double – pipe heat exchanger

ii. Shell and tube heat exchanger

iii. Extended – surface exchangers

iv. Spiral plate exchanger

v. Graphic block heat exchangers

vi. Scrap surface exchanger.


Terms of Use: This is an academic paper. Students should NOT copy our materials word to word, as we DO NOT encourage Plagiarism. Only use as a guide in developing your original research work. Thanks.

Disclaimer: All undertaking works, records, and reports posted on this website, eprojectguide.com are the property/copyright of their individual proprietors. They are for research reference/direction purposes and the works are publicly supported. Do not present another person’s work as your own to maintain a strategic distance from counterfeiting its results. Use it as a guide and not duplicate the work in exactly the same words (verbatim). eprojectguide.com is a vault of exploration works simply like academia.edu, researchgate.net, scribd.com, docsity.com, course hero, and numerous different stages where clients transfer works. The paid membership on eprojectguide.com is a method by which the site is kept up to help Open Education. In the event that you see your work posted here, and you need it to be eliminated/credited, it would be ideal if you call us on +2348064699975 or send us a mail along with the web address linked to the work, to eprojectguide@gmail.com. We will answer to and honor each solicitation. Kindly note notification it might take up to 24 – 48 hours to handle your solicitation.

Material Information
  • ₦4,000.00 1 Price:
  • 61 2 No. of Pages:
  • 5 3 No. of Chapters:
  • No 4 Has Implementation:
FOR ENQUIRIES WE ARE AVAILABLE 24/7

Contact us on

DEPARTMENT
LAW